iR-gas Carbon Dioxide (CO₂) Gas Detector 4350
The GDA 4350 is a 3 wire Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO₂) sensor. It gives a 4-20 mA, 0-20 mA, 0-5 V or 0-10 V o/p over the range of the sensor. Low-Temperature version is available.
Our expert team are here to help answer any questions you have and provide customised solutions. Send an enquiry today.
Showing 1–16 of 18 results
The GDA 4350 is a 3 wire Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO₂) sensor. It gives a 4-20 mA, 0-20 mA, 0-5 V or 0-10 V o/p over the range of the sensor. Low-Temperature version is available.
E-Sense is our new signature range of electrochemical gas detector. This versatile unit boasts several great features including: 2 or 3 wire operation, ability in the the 3 wire mode to be able to connect to either 4-20mA or 0-20mA controllers, it also boasts the ability to change the sensor detection range by half, other…
E-Sense is our new signature range of electrochemical gas detector. This versatile unit boasts several great features including: 2 or 3 wire operation, ability in the the 3 wire mode to be able to connect to either 4-20mA or 0-20mA controllers, it also boasts the ability to change the sensor detection range by half, other…
Meet our Infrared CO₂ Gas Detector iR-gas 4370 Brass stinting The Infrared CO2 gas detector, iR-gas 4370, is designed for use in safe area applications. This infrared CO2 sensor uses the latest laser semiconductor technology for the detection of carbon dioxide (CO2). This Infrared CO2 and electronics are one homogenous unit and must never be…
The iR-gas Flush Mounted Carbon Dioxide (CO2) is a 3 wire 4-20 mA Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO₂) sensor. It gives a 4-20 mA o/p over the range of the sensor. Designed for applications where low-profile intrusion into a room space is required.
Our refrigerant gas detector with an infrared sensor, “iR-gas” functionality, is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas detector with an enabled infrared sensor is designed to connect to a GDA gas detection controller or similar BMS system. This is to control alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.
The refrigerant gas detector enabled with an Infrared Sensor, contains a Non-Dispersive Infra-Red (NDIR) gas sensor, operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Also, this sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.
Our iR-gas refrigerant gas detector has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.
Range of Refrigerant gases: r134a, r410, r32, r123, r22, among others.
E-Sense is our new signature range of electrochemical gas detector. This versatile unit boasts several great features including: 2 or 3 wire operation, ability in the the 3 wire mode to be able to connect to either 4-20mA or 0-20mA controllers, it also boasts the ability to change the sensor detection range by half, other…
E-Sense is our new signature range of electrochemical gas detectors. This versatile unit boasts several great features including 2 or 3 wire operation, ability in the the 3 wire mode to be able to connect to either 4-20mA or 0-20mA controllers, it also boasts the ability to change the sensor detection range by half, other…
Our refrigerant leak detector with an infrared sensor functionality is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas leak detector is designed to connect to a GDA gas detection controller or similar BMS system. This is to control alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.
The refrigerant gas leak detector with an Infrared Sensor, contains a Non-Dispersive Infra-Red (NDIR) gas sensor, operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Also, this sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.
Our Flush Mounted Refrigerant Gas Leak Detector, iR-gas 3160, is suitable for indoor use only.
For external environments, contact our specialist advice from GDA.
The iR-gas mounted refrigerant gas has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.
Range of Refrigerant gases: r134a, r410, r123, r22, among others.
E-Sense is our new signature range of electrochemical gas detector. This versatile unit boasts several great features including: 2 or 3 wire operation, ability in the the 3 wire mode to be able to connect to either 4-20mA or 0-20mA controllers, it also boasts the ability to change the sensor detection range by half, other…
Meet our E-Sense Oxygen (O2) Electrochemical Gas Detector E-Sense is our new signature range of the electrochemical gas detectors. This versatile unit boasts several great features including: 3 wire operation, ability in the 3 wire mode to be able to connect to either 4-20mA or 0-20mA controllers, it also boasts the ability to change the…
Our flammable gas detector GTD-3000Ex has been developed to detect flammable gas leaks from industrial sites, factories, gas storage, and manufacturers that produce or use flammable gases to prevent accidents.
The GTD-3000Ex flammable gas detector is installed in areas where it is a risk for flammable gas exposure and is continuously monitored. It displays measurements on built-in displays (LCD) of the detector and provides an Analog 4~20 mA standard output signal. Also, for Analog 4~20 mA standard output, output signal transmission length between detector and receiver can be connected up to 2,500 m. The GTD-3000Ex flammable gas detector must be used at a height below 1,000 m above sea level.
Meet our GTD-2000Tx Oxygen & Toxic Gas Detector IECEx The oxygen & toxic gas detector GTD-2000Tx also known as a toxic gas alarm, was developed to prevent accidents caused by toxic gases in hazardous spaces, such as plants, toxic gas storage, and factories. When this toxic gas detector is installed will continuously detect the gas…
Continuous detection of VOC gas in explosion hazardous area with flameproof structure Self-diagnosis function with built-in Microprocessor Excellent selectivity by adapting detection principle only for toxic gases & oxygen Superior performance for detecting toxic gases below TLV Multi-functions and high quality with low cost of ownership Built-in backlight LCD or OLED display Easy configuration of…
The continuous detection of flammable gases in explosion hazardous areas with flameproof structure.
Some technical features: The Self-diagnosis function with built-in Microprocessor Detection gas from low to high concentration owing to various detection principles. Stable quality and proved detection principle for service life. Built-in backlight LCD or OLED display. Easy Configuration of monitoring by HART communication. Auto calibration and program setting with a magnet bar. 4-20mA (Current source or sink) output signal. Calibration and maintenance by one man with the alarm unit (GTL-100): Normal: Green LED, Alarm: Red LED, Buzzer (95 dB), and rouble: Yellow LE.
Continuous detection of flammable, CO2, CO and N2O gases in explosion hazardous area with flame proof structure State-of-the art infrared detection principle Long service life time (more than 5 years) Operation in non oxygen environment Self diagnosis function with built-in Microprocessor Fast response time(
Copyright © 2021 Gas Detection (Australia) Pty Ltd
ABN 74 124 402 231