GDA 2525: Carbon Monoxide Gas Sensor (4-20 mA o/p)

The GDA 2525 Carbon Monoxide gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical carbon monoxide sensor unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2526: Ammonia Gas Sensor (0-100 ppm, 4-20 mA o/p)

The GDA 2526 Ammonia gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.


DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2527: Nitrogen Dioxide Gas Sensor (0-20 ppm, 4-20 mA o/p)

The GDA 2527 Nitrogen Dioxide gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2528: Oxygen Gas Sensor (0-25% Vol, 4-20 mA o/p)

The 2528 Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2529: Hydrogen Sulphide Gas Sensor (0-100 ppm, 4-20 mA o/p)

The GDA 2529 Hydrogen Sulphide gas sensor is a 2 wire 4-20 mA loop Powered device. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2530: Sulphur Dioxide Gas Sensor (0-20 ppm, 4-20 mA o/p)

The GDA 2530 Sulphur Dioxide gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2560: Flammable Gas Sensor (0-100% LEL, 4-20 mA o/p)

The GDA 2560 Flammable gas sensor [Hydrogen, Methane, Butane, Propane, Acetylene, and Ammonia] is a 3 wire (24 VDC) 4-20 mA device. This gas sensor is designed to be used areas classed as NON hazardous. It has an electro-resistive catalytic sensing element which is temperature controlled and easily replaceable.


DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 2625: Carbon Monoxide Gas Sensor (4-20 mA, 0-5 V, 0-10 V o/p)

The GDA 2625 Carbon monoxide gas sensor is a further enhancement of the GDA 2525 Carbon monoxide gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA

GDA 2626: Ammonia Gas Sensor (0-100 ppm, 4-20 mA, 0-5 V, 0-10 V o/p)

The GDA 2626 Ammonia gas sensor is a further enhancement of the GDA 2526 Ammonia gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA

GDA 2627: Nitrogen Dioxide Gas Sensor (0-20 ppm, 4-20 mA, 0-5 V, 0-10 V o/p)

The GDA 2627 Nitrogen Dioxide gas sensor is a further enhancement of the GDA 2527 Nitrogen Dioxide gas sensor that allows AC and DC operation as well as providing the option of 4-20 mA, 0-10 V, and 0-5 V operation. The additional voltage o/p can be used on BMS systems that use voltage inputs as opposed to current input. It has an electrochemical gas sensing unit which is temperature compensated. The gas sensor element is on a pluggable lead to allow ease of replacement. The nitrogen dioxide gas sensor electronics are housed in a robust ABS sun tolerant plastic enclosure rated IP65; the sensor head and its electronics are housed in a metal enclosure giving it excellent RFI and EMC compatibility. The sensor head is fitted with a splash proof cover giving an IP62 rating.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA

GDA 2628: Oxygen Gas Sensor (0-25% vol, 4-20 mA, 0-5 V, 0-10 V o/p)

The GDA 2628 Oxygen gas sensor is a further enhancement of the GDA 2528 Oxygen gas sensor that allows AC and DC operation as well as providing the option of 4-20 mA, 0-10 V and 0-5 V operation. The additional voltage o/p can be used on BMS systems that use voltage inputs as opposed to current input. It has an electrochemical gas sensing unit which is temperature compensated. The gas sensor element is on a pluggable lead to allow ease of replacement. The oxygen gas sensor electronics are housed in a robust ABS sun tolerant plastic enclosure rated IP65; the sensor head and its electronics are housed in a metal enclosure giving it excellent RFI and EMC compatibility. The sensor head is fitted with a splash proof cover giving an IP62 rating.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA

GDA 2629: Hydrogen Sulphide Gas Sensor (0-100 ppm, 4-20 mA, 0-5 V, 0-10 V o/p)

The GDA 2629 Hydrogen Sulphide gas sensor is a further enhancement of the GDA 2529 Hydrogen Sulphide gas sensor that allows AC and DC operation as well as providing the option of 4-20 mA, 0-10 V and 0-5 V operation. The additional voltage o/p can be used on BMS systems that use voltage inputs as opposed to current input. It has an electrochemical gas sensing unit which is temperature compensated. The gas sensor element is on a pluggable lead to allow ease of replacement. The hydrogen sulphide gas sensor electronics are housed in a robust ABS sun tolerant plastic enclosure rated IP65; the sensor head and its electronics are housed in a metal enclosure giving it excellent RFI and EMC compatibility. The sensor head is fitted with a splash proof cover giving an IP62 rating.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA

GDA 2630: Sulphur Dioxide Gas Sensor (0-20 ppm, 4-20 mA, 0-5 V, 0-10 V o/p)

The GDA 2630 Sulphur Dioxide gas sensor is a further enhancement of the GDA 2530 Sulphur Dioxide gas sensor that allows AC and DC operation as well as providing the option of 4-20 mA, 0-10 V and 0-5 V operation. The additional voltage o/p can be used on BMS systems that use voltage inputs as opposed to current input. It has an electrochemical gas sensing unit which is temperature compensated. The gas sensor element is on a pluggable lead to allow ease of replacement. The sulphur dioxide gas sensor electronics are housed in a robust ABS sun tolerant plastic enclosure rated IP65; the sensor head and its electronics are housed in a metal enclosure giving it excellent RFI and EMC compatibility. The sensor head is fitted with a splash proof cover giving an IP62 rating.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA

GDA 3100: Refrigerant Gas Detector

This detector detects generally used refrigerant gases (R22, R123, R134a, R404, R407, R410 etc) in the range 0-1000ppm. Each dectector is calibrated to a specific gas type. It has a configurable analog output, 4-20 mA; 0-20 mA; 0-5 V; 0-10 V. There is also a volt free relay which can be user programmed to operate anywhere within the sensor range. The unit is powered from 24 VDC.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 3160: Flush Mount Refrigerant Gas Detector

The GDA 3160 is a low profile wall mounted refrigerant detector for use in offices and laboratories where a gas sensor needs to appear non obtrusive. It is designed to fit into a Clipsal double gang GPO wall mount.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 3300: Sulphur Hexafluoride (SF₆) Gas Detector

The GDA 3300 SF6 detector provides reliable long term detection of SF6 gas at low levels. The available o/p’s are 4-20 mA, 0-20 mA, 0-10 V, 0-5 V. There is also a user relay (SPCO) that operates at a user defined level.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 4350: Carbon Dioxide Gas Sensor

The GDA 4350 is a 3 wire 4-20 mA Non Dispersive Infra red (NDIR) Carbon Dioxide sensor. It gives a 4-20 mA o/p over the range of the sensor. Low temperature version and an process version using an BSP connection are available.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 4360: Flush Mount Carbon Dioxide Gas Sensor

The GDA 4360 is a 3 wire 4-20 mA Non Dispersive Infra red (NDIR) Carbon Dioxide detector. It gives a 4-20 mA o/p over the range of the sensor. Designed for applications where low profile intrusion into a room space is required. The unit fits into a GPO Clipsal spacing using P clamps. It uses laser LED to give reliable performance. Calibration for non critical safety applications is every 3 years. There is a low temperature version (suffix LT) which operates from - 25°C to 45°C.


DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 7228: Flush Mount Oxygen Gas Sensor

The 7228 Flush Mount Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen. It has an electrochemical gas sensing unit which is temperature compensated. The gas sensor element is on a pluggable lead allow ease of replacement. It is designed to fit into a Clipsal double gang GPO wall mount. The total protrusion from the wall is 13 mm; the sensor head and its electronics are housed in a metal enclosure giving it excellent RFI and EMC compatibility.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

SENKO SI-100: Fixed Gas Detector

SI-100 is a IEC Ex fixed gas detector installed in a place where potential gas hazard occurs to measure oxygen, toxic gas and combustible gas.

IECEx Approved

SENKO SI-100C: Fixed Gas Detector

SI-100C is a IEC Ex fixed gas detector installed in a place where potential gas hazard occurs to measure oxygen, toxic gas and combustible gas without a LCD display.

IECEx Approved